设备尺寸(W*D*H): 4290x1466x1439mm
设备重量: 约:2100 kg
电源要求: To be check
气源要求: N/A
设备简介:VisionXS The flexible Reflow Soldering System with futures As a co-founder of modern ReflowConvection-Soldering Systems the company Rehm has been established successfully since 1990 in the national market as well as worldwide. The know-how and experience in reflow technology of many years is now integrated in the VisionXS-series. Optimized for customer requirements the VisionXS stands for productivity and flexibility.展开更多
| PROCESS CHAMBER HEATING | |
|---|---|
Length  | 2100mm  | 
Quantity of preheating zones  | 4  | 
Length of preheating zones  | 1400mm  | 
Quantity of peak zones  | 2  | 
Length of peak zones  | 700mm  | 
Max. permissible soldering temperature : preheating zones  | 300°C  | 
Max. permissible soldering temperature : peak zones  | 350°C  | 
Heat transfer through  | Forced convection  | 
Gas circulation per heating zone  | max.350m3/h  | 
Warm up time  | ca.30min/approx30min  | 
Cross profile (Delta T = Tmax _ Tmin)  | ±2,5Kelvin  | 
type  | type 422  | 
| COOLING ZONE | |
|---|---|
Length  | 700mm  | 
| MESH BELT CONVEYOR | |
|---|---|
Width  | 461mm  | 
| PIN CHAIN CONVEYOR | |
|---|---|
Transport Level  | 900±75mm  | 
Width, single conveyor ±0,5 mm / without CBS  | 50–400mm;
Option1:50–460mm;
Option2:50–508mm  | 
Width, single conveyor ±0,5 mm / with CBS  | 65–400mm;
Option1:100– 460mm;
Option2:140– 508mm  | 
Tolerance conveyor speed (1 % per 1800 mm/min)  | <=18mm/min  | 
| CENTRE SUPPORT | |
|---|---|
Lash heigt  | Lash stand off:16mm  | 
Distance to fixed rail lowered  | 20mm  | 
Center Support active Width  | 50–340mm;
Option1:50 –380mm;
Option2:50–390mm  | 
CBS Low (Parking Position)  | 14mm  | 
| OPERATING DATA | |
|---|---|
Maximum noise level  | 75dBA  | 
Room temperature  | between15°Cand32 °C  | 
Humidity  | between30%and75%  | 
Oxygen of peak zones  | <100ppm  | 
| VOLTAGE SUPPLY CONSUMPTION | |
|---|---|
Energy consumptions standby-mode  | 6KW  | 
Connected load  | 41KW  | 
Operating capacity  | 7,5KW	  | 
| COOLING WATER AT EXTERNAL COOLING | |
|---|---|
Connection  | M28x1,5(22mmCu Rohr/0,87in Cu Tube)  | 
Cooling water flow  | between10–20l/min (according to temperature)  | 
Operating pressure  | min.2bar–max.5ba  | 
Differential pressure between forward and return run  | min.0,5bar  | 
| NITROGEN SUPPLY | |
|---|---|
Connection  | M1x1(12mmCu Rohr)/M 16×1(12mm/0,472in Cu-Tube)  | 
Nitrogen supply pressure  | min.7bar–max.10 bar  | 
Operating pressure  | 5bar  | 
Nitrogen consumption single conveyor at <200 ppm in peak
max. 200 mm at min. 1 PCB gap  | ca.19m3/h  | 
Nitrogen consumption with N2-control in Standby Mode 200 mm transport width.  | ca.16m3/h	  | 
| EXHAUST PROCESS | |
|---|---|
Exhaust socket: diameter  | 2x100mm Ein-bzw. Auslauf/2x3,9in In-and Outlet  | 
Exhaust at min. 5 mbar underpressure  | 2x200m3/h  | 
Exhaust temperature  | <50°C  | 
| System configuration VisionX-Series | |
|---|---|
Single lane  | Cold condensation with cooler/filter units only nitro systems  | 
| System configuration VisionX-Series optiona | |
|---|---|
Mesh belt  | Product management  | 
Traceability packages  | Process interlock  | 
ProCap  | MES-Option ROI  | 