科Seica THT自动光学检测机PILOTV 8 HR

Equipment Size (W*D*H): 1265 mmX1750 mmX1800mm

Equipment Weight: 1400kg

Power Requirements: AC220V 50HZ

Air Source Requirements: 0.5±0.05Mpa

Equipment Introduction:The PILOT V8 HR NEXT>SERIES is based on the Seica VIP platform, which includes the innovative VIVA NEXT> software. Test program development is organized in 3 simple steps: “Prepare”, “Verify” and “Test”, where the user is guided through a series of automated operations in an intuitive, self-explanatory environment, drastically reducing programming time and minimizing errors and omissions, ensuring the quality of the final test programShow More

Equipment Parameters
Equipment Documents
Parts List

Equipment Parameters

PROBES AND CAMERAS
Probes Position - Test Side
Front/Rear
Standard Configuration
6 Standard Probe 1 CCD HR 10 MegaPixel Color Cameras (front) 1High Resolution Probes(front)
Number of CCD view probes Color Cameras
2 (1 front, 1 rear)
Maximum Digital Embedded Channels
4
Marker Recognition
Automatic
UUT Planarity Compensation (by Laser)
Automatic
BOARD CLAMPING SYSTEM
Board Clamping System
Manual (Dual Action)
Active Test Area
500 x 450 mm
Minimum Board Size
20 x 20 mm
Minimum Board Thickness
0.3 mm
Maximum Board Thickness
7 mm
Maximum Thickness testable
13 mm
UUT Clamping Clearance
2 mm
UUT Clearance
19 mm Top, 40 Bottom (Standard Configuration) 19 mm Top, 19 Bottom (Optional Configuration)
PROBE FEATURES
Minimum Pad Pitch
150 µm
Minimum Pad Size
75 µm Standard Electrical Probe 40 µm High Resolution Probe
XY axis resolution (brushless motor)
2.5 µm
Z axis resolution (linear motor)
1 µm
Z-axis Travel
-3.0 mm to 40 mm (programmable)
Contact Force
Standard Probe 10 g – 100 g (programmable) High Resolution Probe 1 g – 13 g (programmable)
TESTS AND MEASUREMENTS
Voltage Generator 1 (DRA)
DC/AC ±1 mV to ±10 V (±0.1%)
Voltage Generator 2 (DRB)
DC/AC ±1 mV to ±10 V (±0.1%)
Voltage Generator 3 (DRC)
DC/AC ±25 mV to ±100 V (±0.2%)
Current Generator
DC/AC ±1 nA to ±0.5 A (±0.1%)
Waveform Generator 1 (DRA)
Sin, Tri, Arbitrary 1 Hz to 3 MHz (±1 mHz), ±10 Vmax
Waveform Generator 2 (DRC)
Sin, Tri, Arbitrary 1 Hz to 10 kHz (±10 mHz), ±100 Vmax
Voltage Measurements
DC/AC ±200 µV to ±100 V
Current Measurements
DC/AC ±3 nA to ±0.5 A
Frequency Measurement
0.1 Hz to 50 MHz
Digital Embedded Channel
±12 V - 500 mA - 10 MHz
Resistance Measurement
1 mΩ to 100 MΩ
Capacitance Measurement
1 pF to 1 F
Inductor Measurement
1 µH to 1 H
Zener Measurement
up to 100 V (200V option)
Visual Inspection
Automatic

Equipment Documents

Parts List